6-8
Storage Manager
Device
The unique ID for that device. For an array, this is the lowest ID among
the drives that make up the array.
LUN
Logical Unit Number for that device (normally 0).
NOTE Array groups are automatically assigned an address that
corresponds to the lowest logical device address used by a
device in that array group. For example, if the lowest member
device address for an array is HBA:0 Bus:1 ID:12 LUN:0, the
LSU address will be HBA:0 Bus:1 ID:12 LUN:0.
When an Array Group has been created, its logical device address will not
change if the drive with the lowest ID is replaced by a Hot Spare. When a
Hot Spare replacement occurs, the failed drive automatically becomes the
new Hot Spare. If you choose not to use that drive as a Hot Spare, Storage
Manager will prompt you to select an unused logical device address for
that drive.
Status
Status is reported by SmartRAID V controllers for arrays and drives.
Some status conditions are indicated by Storage Manager through status
flags on the drive or array icons. View the information window for the drive
or array to see specific status information. Changes in status conditions
are logged and can also be broadcast to selected recipients.
The following table lists the general status conditions that can be indicated
for drives or arrays. The Status field in the device or array information
window displays additional information for any reported status condition
other than Optimal.