Acer A101 Guía de usuario Pagina 121

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 224
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 120
Machine Maintenance Procedures 3-21
3G Module Installation 0
1. Connect RF cable (F) to IO board connector. (Figure 3-28)
2. Install 3G module (A) on mainboard. (Figure 3-27)
3. Install and secure screw (E) to mainboard.
CAUTION:
!
Route the WLAN antenna around the IO board FPC to prevent it from being
disconnected from mainboard.
4. Connect WLAN antenna (D) to mainboard connector. (Figure 3-26)
5. Connect GPS (C) and RF (B) cables to 3G module connectors labeled auxiliary and main.
6. Install battery.
ID Size Quantity Screw Type
E M2.0x3.0 1
Vista de pagina 120
1 2 ... 116 117 118 119 120 121 122 123 124 125 126 ... 223 224

Comentarios a estos manuales

Sin comentarios